ETS 64-R
0548-990-61---70g_2019.10.indd
0548-990/62g
Page 50 of 95
Mounting and operating instructions
5.5.1
Motorised lock with direct connection to motor coil
Some motorized locks can be directly controlled from the control unit of the swing door drive
mechanism (direct connection of motor coil). In order to enable this configuration, the motorized
lock must fulfill the following requirements:
• 24 VDC / max. 1,5 A
• Possibility to connect a release signal directly on the motorized lock.
5.5
Motorized lock
The swing door drive mechanism and its control unit are always configured as Master. All the
commands are transmitted to this control unit. The latter then unlocks/locks the motorized lock.
Attention:
The motorized lock must be homologated together with the fire safety profile system!
Functional performance:
Opening command
Impulse and permanent command transmitted to motorised lock
(CONFIG Unlock: IMPULS or PERMAN)
Locking latch opens
Starting delay TDelay to be set between 0,0...4,0 s or a feedback
can be connected on terminal 32
Drive unit opens
Hold-open time expires
Drive unit closes
Motorised lock locks
provided that no command for the motorized lock is pending (to
be set under CONFIG Unlock = PERMAN, operating modes Automa
-
tic, Exit, Manual)
Note:
The following lists of motorized locks are not necessarily exhaustive. Please take into
account the modifications communicated by the motorized lock manufacturers! Also se
wiring diagram E4-0142-180_ECO in the appendix.
Designations
Terminals
Remarks
Swing door drive mechanism
1
24 VDC
30
EL-NO
28
GND
32
EL-Fb
-
FlipLock drive
1
3
2
5
CONFIG
EL-Fb = N.C.
PARAMETER
TDelay = 0
Содержание ETS 64-R
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......
Страница 100: ......
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 107: ......
Страница 108: ......
Страница 109: ......
Страница 110: ......
Страница 111: ......
Страница 112: ......