Firmware V3.00
05.08.2019
86/100
9.5 Menu 3 Clock
CLOCK POS: XXXXX
1 Current Time
Move to menu 3-1
2 Defrost Timer
Move to menu 3-2
•
Menu 3-1 Current Time
CLOCK POS: XXXXX
Entry
Default
Date: XX dd.mm.yy
Display and enter current weekday, date
dd.mm.yy
Time: hh.mm
Display and enter current time
hh.mm
Daylight Saving X
Display and enter automatic daylight saving change (Y/N)
↑, ↓, (Y/N)
J
•
Menu 3-2 Defrost Timer
DEFR.TIMER POS:
XXXXX
Entry
Default
Safe Defr. Time XXX m
Safe defrost time for maximum allowed duration of internal
defrosting
0..120
60 min
Defr. 1 xxxxx hh:mm
First defrost start time with internal defrosting; weekday,
time
↑, ↓, (Mo-Su etc.) or numbers
(hh:mm)
Mo-Su06:00
Defr. 2 xxxxx hh:mm
Second defrost start time with internal defrosting;weekday,
time
↑, ↓, (Mo-Su etc.) or numbers
(hh:mm)
Mo-Su18:00
...
Defr. 14 xxxxx hh:mm
When connected to the CAN bus, the default time is provided via the time master (system centre /
store computer, operator terminal). Any entry made will then be overwritten by the default value.
Содержание UA 410 L AC