6.1.1 DIN rail mounting of the Temperature Data Logging Controller
The Temperature Data Logging Controller for discounter is attached to the DIN rail (35 mm) using two retaining
springs. The DIN rail must have a minimum height of 5 mm.
The power loss of the device is approx. 11 VA and must be taken into account for the installation.
The Temperature Data Logging Controller may only be mounted on a Cap (DIN) rail and operated as
an integrated regulation and control device (EN60730). All leads running to and from the case
controller - especially those of the CAN bus - must be shielded (cable type: LiYCY)! No shielding is
required on sensor leads when installed exclusively inside the refrigerated display case and when
external interference (for example from parallel power wires) is not to be expected (see operating
instruction
"
Grundlagen und allgemeine Sicherheits- und Anschlusshinweise
"). As a general rule, care
should be taken to ensure that signal leads and leads carrying a supply voltage are routed through
separate cable channels.
Electrical enclosure and dimensions are listed in Section
.