manualshive.com logo in svg
background image

Page 7 of 12

Torus

™ 

Flash Patterns

Order

Flash Pattern

1

Cycle Flash (Default)

2

NFPA Quad Flash 80 FPM

3

Quad Pop Flash 70 FPM

4

Steadyburn

5

Five Flash 70 FPM

6

Triple Flash 70 FPM

7

Double Flash 70 FPM

8

Single Flash 70 FPM

9

Quad Pop Flash 70 FPM

10

Triple Pop Flash 70 FPM

11

Mod Flash

12

Cycle Flash 150 FPM

13

Five Flash 150 FPM

14

Quad Flash 150 FPM

15

Triple Flash 150 FPM

16

Double Flash 150 FPM

17

Single Flash 150 FPM

18

Single Flash 250 FPM

19

Single Flash 375 FPM

TABLE 2

FIGURE 6

For Torus™ (6 or 9 LED) style modules, the flash pattern on each individual module can be cycled to the next flash pattern (shown in Table 2) 

by momentarily shorting together the JP1 pins with a wire or the blade of a screwdriver as shown in FIGURE 6. The module will reset to the 

default flash pattern when the JP1 pins are shorted together for 5 seconds or more. Module pairs connected by a sync wire must be individu

-

ally set to the same flash pattern to properly synchronize.

Содержание DuoBeam

Страница 1: ...h live electrical connections 3 This product must be properly grounded Inadequate grounding and or shorting of electrical connections can cause high current arcing which can cause personal injury and...

Страница 2: ...s vehicle upholstery vehicle support members etc that could be damaged Permanent Mount 1 Insert carriage bolts into track 2 Place spacer over bolts as shown in FIGURE 1 3 Align bolts with pre drilled...

Страница 3: ...the light bar and loosely attach the mounting brackets 2 Place the lightbar on the vehicle and slide the mounting brackets into position 3 Secure the brackets to the lightbar with the supplied washer...

Страница 4: ...he best fit Some additional bending of brackets may be necessary in some cases to achieve a satisfactory fit 3 Attach bracket assembly to mirror supports with U bolts Position bracket assembly as desi...

Страница 5: ...and properly sized to protect the wiring and devices 4 Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosio...

Страница 6: ...M 15 Modular Flash The DuoBeam can be populated with one of two different module types PriZm or Torus For PriZm 8 or 12 LED style modules the flash pattern on each individual module can be cycled to t...

Страница 7: ...Double Flash 150 FPM 17 Single Flash 150 FPM 18 Single Flash 250 FPM 19 Single Flash 375 FPM TABLE 2 FIGURE 6 For Torus 6 or 9 LED style modules the flash pattern on each individual module can be cyc...

Страница 8: ...single emergency level mode 1 Power up the unit and apply power to the level mode wire s you wish to change see TABLE 4 The unit will flash the default pattern 2 Momentarily touch the GRN pattern sele...

Страница 9: ...ernating 70 FPM 7 Double FLash Simultaneous 70 FPM 8 Double FLash Alternating 70 FPM 9 Variable Single Flash Simultaneous 10 Variable Single Flash Alternating 11 Cycle Flash Simultaneous 150 FPM 12 Cy...

Страница 10: ...unt Kit EZ21DBMM Accessories Lens Retaining Clip EZ2127LC Lens Retaining Clip Black EZ2127LCB Modules TR6 centrally controlled EZ21CC6X TR9 centrally controlled EZ21CC9X TR6 independent flashing EZ21I...

Страница 11: ...the prior steps in reverse order Torque screw s securing the light head assembly to the mounting bracket using 10 in lbs Torque screws securing the mounting bracket to the extrusion using 50 in lbs Tr...

Страница 12: ...CONSTITUTE WARRANTIES Remedies and Limitation of Liability ECCO S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST ECCO REGARDING THE...

Отзывы: