TR Series Wiring
A TR series DuoBeam™ has a single cable with 7 colored wires. A dedicated ground wire, a dedicated power wire and five colored control
wires which run through the main driver board.
The 16 AWG black ground wire should be connected directly to the battery. The 16 AWG red power wire requires a constant 10 to 16V(+)
power source with a customer supplied in line
15A
fuse.
The five control cable wires (listed in TABLE 3 below) routed through the driver board carry only low current (30 mA average) input signals to
control the DuoBeam™ functions and must be routed to the output of a control switch (or directly to multiple switches).
TABLE 3
Emergency Mode Flash Pattern Selection
There are seven customizable emergency flash pattern modes available based on the wire combinations shown in TABLE 4. When using
individual switches, make sure to configure all possible switch combinations.
To change a flash pattern on a single emergency level mode:
1. Power-up the unit and apply +power to the level mode wire(s) you wish to change (see TABLE 4). The unit will flash the default pattern.
2. Momentarily touch the GRN pattern select wire to (+) power to cycle through to the next flash pattern shown on TABLE 5.
3. To reset the flash pattern to the factory default, hold the GRN pattern select wire to (+) power for ~5 seconds.
Standard TR Function Wire Definitions
Function Wire Color
Function
Description
BLU
L1
Level 1 Emergency Mode
ORG
L2
Level 2 Emergency Mode
YEL
L3
Level 3 Emergency Mode
GRN
Pattern Select
WHT
Lightbar Dim
Set LEDs to DIM mode
Notice:
When the GRN Pattern Select wire is connected to +power alone, test mode is enabled to excercise all outputs in
sequence.
Level Mode Combinations
Flash Pattern Modes Function Wire Color(s)
Pattern
Description
FPM
L1
BLU
1
Cycle Flash Simultaneous
70
L2
ORG
1
Cycle Flash Simultaneous
70
L3
YEL
1
Cycle Flash Simultaneous
70
L1 + L2
BLU & ORG
1
Cycle Flash Simultaneous
70
L1 + L3
BLU & YEL
1
Cycle Flash Simultaneous
70
L2 + L3
ORG & YEL
1
Cycle Flash Simultaneous
70
L1 + L2 + L3
BLU, ORG & YEL
1
Cycle Flash Simultaneous
70
TABLE 4