Notes:

1.  Larger wires and tight connections will provide longer service life for components.  For high current wires it is highly recommended 

     that terminal blocks or soldered connections be used with shrink tubing to protect the connections.  Do not use insulation displacement 

     connectors (e.g., 3M Scotchlock type connectors). 

2.  Route wiring using grommets and sealant when passing through compartment walls.  Minimize the number of splices to reduce

     voltage drop.  High ambient temperatures (e.g., under-hood) will significantly reduce the current carrying capacity of wires, fuses, and 

     circuit breakers. All wiring should conform to the minimum wire size and other recommendations of the manufacturer and be protected 

     from moving parts and hot surfaces.  Looms, grommets, cable ties, and similar installation hardware should be used to anchor and 

     protect all wiring.

3.  Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring 

     and devices.

4.  Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from 

     corrosion and loss of conductivity.  

5.  Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.

6.  Circuit breakers are very sensitive to high temperatures and will “false trip” when mounted in hot environments or operated close to 

     their capacity.

            

Important!

This unit is a safety device and it must be connected to its own separate, fused power point to assure its continued operation should any 

other electrical accessory fail.  Do not wire in parallel with any other accessory.

Wiring Instructions:

            

          

 Caution: 

Disconnect the battery before wiring up the lightbar, to prevent accidental shorting, arcing and/or electrical shock.

!

IF Series Wiring

An IF series DuoBeam™ has a dedicated ground wire and one or more +power wires routed to the modules. The black ground 

wire should be connected directly to the battery. The amp ratings for each module type are detailed in the specifications secion 

of this installation guide.

Содержание DuoBeam

Страница 1: ...h live electrical connections 3 This product must be properly grounded Inadequate grounding and or shorting of electrical connections can cause high current arcing which can cause personal injury and...

Страница 2: ...s vehicle upholstery vehicle support members etc that could be damaged Permanent Mount 1 Insert carriage bolts into track 2 Place spacer over bolts as shown in FIGURE 1 3 Align bolts with pre drilled...

Страница 3: ...the light bar and loosely attach the mounting brackets 2 Place the lightbar on the vehicle and slide the mounting brackets into position 3 Secure the brackets to the lightbar with the supplied washer...

Страница 4: ...he best fit Some additional bending of brackets may be necessary in some cases to achieve a satisfactory fit 3 Attach bracket assembly to mirror supports with U bolts Position bracket assembly as desi...

Страница 5: ...and properly sized to protect the wiring and devices 4 Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosio...

Страница 6: ...M 15 Modular Flash The DuoBeam can be populated with one of two different module types PriZm or Torus For PriZm 8 or 12 LED style modules the flash pattern on each individual module can be cycled to t...

Страница 7: ...Double Flash 150 FPM 17 Single Flash 150 FPM 18 Single Flash 250 FPM 19 Single Flash 375 FPM TABLE 2 FIGURE 6 For Torus 6 or 9 LED style modules the flash pattern on each individual module can be cyc...

Страница 8: ...single emergency level mode 1 Power up the unit and apply power to the level mode wire s you wish to change see TABLE 4 The unit will flash the default pattern 2 Momentarily touch the GRN pattern sele...

Страница 9: ...ernating 70 FPM 7 Double FLash Simultaneous 70 FPM 8 Double FLash Alternating 70 FPM 9 Variable Single Flash Simultaneous 10 Variable Single Flash Alternating 11 Cycle Flash Simultaneous 150 FPM 12 Cy...

Страница 10: ...unt Kit EZ21DBMM Accessories Lens Retaining Clip EZ2127LC Lens Retaining Clip Black EZ2127LCB Modules TR6 centrally controlled EZ21CC6X TR9 centrally controlled EZ21CC9X TR6 independent flashing EZ21I...

Страница 11: ...the prior steps in reverse order Torque screw s securing the light head assembly to the mounting bracket using 10 in lbs Torque screws securing the mounting bracket to the extrusion using 50 in lbs Tr...

Страница 12: ...CONSTITUTE WARRANTIES Remedies and Limitation of Liability ECCO S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST ECCO REGARDING THE...

Отзывы: