background image

Page 6 of 12

FIGURE 5

IF Series Flash Pattern Selection

PriZm

™ 

Flash Patterns

Order

Flash Pattern

1

Cycle Flash (Default)

2

NFPA Quad Flash 80 FPM

3

Steady Burn

4

Single Flash 75 FPM

5

Single Flash 150 FPM

6

Single Flash 300 FPM

7

Double Flash 75 FPM

8

Double Flash 150 FPM

9

Triple Pop Flash 75 FPM

10

Triple Flash 150 FPM

11

Quad Pop Flash 75 FPM

12

Quad Pop Flash 150 FPM

13

Five Flash 70 FPM

14

Five Flash 150 FPM

15

Modular Flash

The DuoBeam can be populated with one of two different module types - PriZm™ or Torus™. For PriZm™ (8 or 12 LED) style modules, the 

flash pattern on each individual module can be cycled to the next flash pattern (shown in TABLE 1) by briefly shorting together the 2 short 

pads with a wire or the blade of a screwdriver as shown in FIGURE 5. The modules can be reset to the default flash pattern by shorting the 

pads together for longer than 5 seconds. A thin layer of conformal coat may need to be scraped from the surface of the short pads if the 

modules aren’t changing patterns easily.

TABLE 1

SHORT PADS

Содержание DuoBeam

Страница 1: ...h live electrical connections 3 This product must be properly grounded Inadequate grounding and or shorting of electrical connections can cause high current arcing which can cause personal injury and...

Страница 2: ...s vehicle upholstery vehicle support members etc that could be damaged Permanent Mount 1 Insert carriage bolts into track 2 Place spacer over bolts as shown in FIGURE 1 3 Align bolts with pre drilled...

Страница 3: ...the light bar and loosely attach the mounting brackets 2 Place the lightbar on the vehicle and slide the mounting brackets into position 3 Secure the brackets to the lightbar with the supplied washer...

Страница 4: ...he best fit Some additional bending of brackets may be necessary in some cases to achieve a satisfactory fit 3 Attach bracket assembly to mirror supports with U bolts Position bracket assembly as desi...

Страница 5: ...and properly sized to protect the wiring and devices 4 Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosio...

Страница 6: ...M 15 Modular Flash The DuoBeam can be populated with one of two different module types PriZm or Torus For PriZm 8 or 12 LED style modules the flash pattern on each individual module can be cycled to t...

Страница 7: ...Double Flash 150 FPM 17 Single Flash 150 FPM 18 Single Flash 250 FPM 19 Single Flash 375 FPM TABLE 2 FIGURE 6 For Torus 6 or 9 LED style modules the flash pattern on each individual module can be cyc...

Страница 8: ...single emergency level mode 1 Power up the unit and apply power to the level mode wire s you wish to change see TABLE 4 The unit will flash the default pattern 2 Momentarily touch the GRN pattern sele...

Страница 9: ...ernating 70 FPM 7 Double FLash Simultaneous 70 FPM 8 Double FLash Alternating 70 FPM 9 Variable Single Flash Simultaneous 10 Variable Single Flash Alternating 11 Cycle Flash Simultaneous 150 FPM 12 Cy...

Страница 10: ...unt Kit EZ21DBMM Accessories Lens Retaining Clip EZ2127LC Lens Retaining Clip Black EZ2127LCB Modules TR6 centrally controlled EZ21CC6X TR9 centrally controlled EZ21CC9X TR6 independent flashing EZ21I...

Страница 11: ...the prior steps in reverse order Torque screw s securing the light head assembly to the mounting bracket using 10 in lbs Torque screws securing the mounting bracket to the extrusion using 50 in lbs Tr...

Страница 12: ...CONSTITUTE WARRANTIES Remedies and Limitation of Liability ECCO S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST ECCO REGARDING THE...

Отзывы: