CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
32 / 116
8
– Show partition arming mode instead of inputs interlocking states. By default
systerm will show violated and interlocked zones on diodes 1-8. Setting this option
will tell the system to show partitoin armind mode on diodes 1-2. Zones states will no
longer be available.
Display scheme:
Led off – partition disarmed
Led on – partition armed in away mode
Led blinking – partition armed in stay mode
You can press
any time to exit without saving changes.
6.7.
USERS REMOTE MANAGEMENT
That function allow to switch on or switch off remote users management. The argument of
the function is BIT type. By pressing key 1, you can switch on/off option. 3 beeps will
confirm the successfully entered function.
<Options>
Where:
Options
– number of option (BIT type parameter):
1
– Users remote management enable – when is swiched on
You can press
any time to exit without saving changes.
6.8.
ZONES CONFIGURATION
The zones can be configured using complex service functions, after activation of which, all
the parameters related to the relevant zone can be given subsequently or in a form of series
of service functions that configure one zone-related parameter.
Codes of zone configuration functions are defined as per the following pattern:
<XX> <Y>
where:
XX –
determines the number of zone from
01
to
07
; entering number
00
will change the
parameters for all zones in the system,
Y
– number of parameter related to a given zone:
0
– complex function, the initiation of which configures the parameters listed below
as another set of parameters;
1
– type of zone response (DEC type parameter):
o
0 – instant
o
1 – delay
o
2 – 24h burglary
o
3 – arming/disarming
o
4 – 24h tamper
o
5 – interior delayed
o
6 – 24h burglary silent
o
7 – 24h fire