CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
109 / 116
11.1.4.2.
CPGETFAILURES
Format:
CPGETFAILURES[= password]
Limitations:
You must know the administrator or user password. Can be executed
by ATS, administrator or user. If the command comes from ATS and
was not authorized with a code, enter the password.
Description
password is the system administrator or user password
The command returns:
CPGETFAILURES:outFailures,powerOutFailures,powerInFailures,keyp
adCommFailures,keypadPowerFailures,otherFailures
Where:
outFailures is a bit-vector informing about the failures of outputs. Bit
1 (counting from 0) means the output 1.
powerOutFailures is a bit-vector informing about the failures of
power supply outputs. Bit 0 means the output KPOUT, bit 1 means
the output AUX1, bit 2 means the output AUX2.
powerInFailures is a bit-vector informing about the failures of power
supply. Bit 0 means the supply network failures, bit 1 means the
battery failure.
keypadCommFailures is a bit-vector informing about the failures of
communication with keypads. Bit 0 means the keypad 1.
keypadPowerFailures is a bit-vector informing about the power
supply failures reported by keypads. Bit 0 means the keypad 1.
otherFailures is a bit-vector determining the current system failures.
The meaning of bits is as follows:
bit 0 – loss of clock
bit 1 – configuration memory failure
CPGETFAILURES:EPERMISIONS
If the specified password is incorrect
CPGETFAILURES:ENOT_ALLOWED
If the command was sent via open SMS
CPDELUSER:EFORMAT