CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
26 / 116
2 – Help alarm activated
Note: Alarms memory is cleared after the system is armed.
5.9.
FAULTS MEMORY
- Display of faults memory
The function displays faults that are present in the system. When the function is activated,
SYSTEM and PROG LEDs are flashing slowly and all faults that are currently present in the
system are displayed. LEDs 1 – 8 display information on the cause of fault. To clear the
faults memory, press
. To exit without clearing the faults memory, press
.
Faults description:
1 –
Sabotage of zones
To display more detailed information about sabotage of zones, press
button.
1 – Sabotage of zone 1
2 – Sabotage of zone 2
7 – Sabotage of zone 7
To return to the main fault menu, press
.
2 –
Fault of outputs 1 – 3
To display more detailed information about fault of outputs, press
button.
1 – Fault of output 1
2 – Fault of output 2
3 – Fault of output 3
To return to the main fault menu, press
.
3 –
Fault of feeding outputs
To display more detailed information about fault of feeding outputs, press
button.
1 – Fault of feeding KP
2 – Fault of feeding AUX1
3 – Fault of feeding AUX2
To return to the main fault menu, press
.
4 –
AC fault
No more detailed information.
5 –
Battery fault
No more detailed information.
6 –
ATS fault
No more detailed information.
7 – Other damages