CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
28 / 116
User’s code is 3446, his duress code is 3447.
User’s code is 3449, his duress code is 3440.
Whenever duress code is input and confirmed by
button, distress event will be sent. It
can be used in every command that requires user authorization, i.e. arming/disarming and
every system option that requires user code, like partition state checking.
Duress code is disabled by default. It can be enabled by the installer or by the configuration
program.
5.13.
EMERGENCY BUTTONS
The keypad of CPX200NB has 3 function keys. Pressing and holding for 3 seconds one of
these keys will generate an alarm
2
corresponding to the key:
– Fire alarm
– Medical alarm
– Panic alarm (burglary)
Note
– for the emergency buttons to work, it is necessary to be in arm/disarm ready mode
and wait at least 10 seconds since last 0-9 key press. You can also press ‘*’ key to clear
keypad buffer and use emergency button after that without any delay.
Fire alarm
– when activated it is signaled on a keypad with all digits blinking. Enter and
confirm any user code to deactivate it.
Medical alarm
– when activated it is signal on a keypad with the ALARM led blinking.
Panic alarm
– not signaled on a keypad.
Every emergency alarm generates an event, that is sent to the server. For emergency
alarms events to be sent, they have to be enabled in the MONITORING tab of the
configuration program (see item 8.6.).
2
Works only with KP16 keypad