CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
19 / 116
4.
ALARM CONTROL UNIT CONFIGURATION
4.1.
ZONE BLOCKING
The zone blocking function allows de-activating stand-by mode of any zones or bypassing
any damaged lines. Also, zones which are not in stand-by mode and which the user has
access to can be blocked. Zones remain blocked until de-arming. System informs the user
about that fact with slowly flashing LED marked with the number of the blocked zone.
Zone blocking:
1.
Enter the number of the function
and confirm with
. Enter the user code
and press
. 3-tone beep will confirm the correct code input.
Note: If incorrect code is entered the keyboard will emit long constant
sound. Enter the correct code once again.
2.
Use buttons numbered 1 to 7 to select zones you want to block.
3.
Change the zones blocking status by pressing numbered buttons (LEDs with relevant
zone number will go on/off). Press
to confirm blocking of selected zones. 3 beeps
will confirm the change. To cancel the entered changes, press
.
4.2.
ADDING A NEW USER
You can add a new user code here. New codes can be added by the administrator only. 3
beeps will confirm the successfully entered function.
Note: Individual codes cannot be the same; if any code is the same as
any other code or any other duress code, it will not be saved.
To add a new user:
1.
Enter the function code
and press
to confirm.
2.
Enter the admin code and confirm it with
. 3 beeps will confirm the correct code
input.
3.
Numbers of already existing users will be displayed.
4.
Enter the ID of newly added user (1 to 8), other than already added ID numbers, and
press
to confirm. Numbers of partitions a new user can have access to will be
displayed.
5.
To activate/deactivate LED of an appropriate partition, press 1 or 2. When the access is
set, press
to confirm. All LEDs shall be off now.
6.
Enter the code of a newly added user (4 to 7 digits) and press
to confirm.
7.
Enter the code of a newly added user again and press
to finish adding or
to
exit without saving changes.