CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
22 / 116
5.
ALARM CONTROL UNIT HANDLING
5.1.
ARMING MODES
Each partition can be armed in one of the following modes
Stay (perimeter) – partition is armed, but only perimeter and perimeter exit zones
violation will cause an alarm
Away (full) – partition is armed and violation of any zone will cause an alarm
User can choose the arming mode or let the system do it for himself.
5.2.
ARMING THE SYSTEM
Stay mode is in fact a part of the Away mode. Every time a correct code is given, the
system will
immediately
arm in the stay mode (provided it has perimeter zones).
Afterwards, the system can automatically arm in the away mode, if proper conditions
were met.
5.2.1.
Stay mode
Arming the partition in stay mode is possibile only if it has perimeter zones assigned to it.
Partition will arm in the stay mode in following cases:
1.
Input the user code, press and hold the
button for 3 seconds
1
.
2.
Input the user cold and press the
button. If the perimeter exit zones is violated
during the exit time countdown, partition will arm in away mode. If perimeter zone is
not violated during the exit time countdown, partition will remain armed in the stay
mode.
5.2.2.
Away mode
In order to arm the partition in the away mode, user has to input his code and press the
button. Exit time countdown will start. Partition will arm in the stay mode in the
following cases:
1.
Partition has perimeter exit zones and at least one of them is violated during the exit
time countdown.
1
Works only with KP16 keypad
Note: If incorrect code is entered the keypad will emit long constant
sound. Repeat the arming process by entering the correct code.
Note: If the partition is not plugged any zones and/or outputs, the
partition is not armed.