CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
85 / 106
Limitations:
Data length to 31 characters, can be changed by ATS only
Description
Configures the APN through which data will be sent by GPRS
10.1.1.2.
UN
Format:
UN=username
Limitations:
Data length to 31 characters, can be changed by ATS only
Description
Sets the user name for APN
10.1.1.3.
PW
Format:
PW=password
Limitations:
Data length to 31 characters, can be changed by ATS only
Description
Sets the password for APN
10.1.1.4.
SERVER
Format:
SERVER=server_address
Limitations:
Data length to 31 characters, can be changed by ATS only
Description
Sets the OSM server address with which the device exchanges data.
adres_serwera can be given in the domain format,
eg.device.mycompany.com domain or IP address, such as 173.194.69.94
10.1.1.5.
PORT
Format:
PORT=port
Limitations:
A number between 1-65535, can be changed by ATS only
Description
Sets the OSM server address with which the device exchanges data
10.1.1.6.
SMS
Format:
SMS=phone_number
Limitations:
Data length to 15 characters, can be changed by ATS only
Description
Sets the phone number for sending SMS with the events in the absence of
GPRS communication. If the number is not configured sending SMS
messages will not be available. phone_number may contain a prefix of the
country.