CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
24 / 106
3.
If partition disarming is selected, the relevant partition will be immediately disarmedEnter
the number of the function
and confirm using
. Then enter the user code and
press
.
Note: If the partition is not plugged any zones and/or outputs, the
partition is not armed.
5.5.
ALARM DISPLAY
If red ALARM LED flashes when the system is armed, it means that while you were absent
some alarms occurred (numbers of lines that initiated them will be displayed as well) which
have already ceased. But, if ALARM LED emits constant light, it means that system still is in
alarm state. Exercise caution! If you suspect any intruder to be present in the facility, leave
the facility immediately and call security guards.
5.6.
ALARM MUTE
1.
To mute (deactivate) the alarm, enter the code and press
. 3 beeps will confirm the
code. Also, the system will be disarmed.
2.
In order to identify the alarm type, please refer to
Alarm Memory chapter of the present
manual.
5.7.
ALARM MEMORY
- Display of alarm memory
The function displays the history of alarms that occurred in the system. When the function is
activated, ALARM and PROG LEDs are flashing slowly and all alarms that occurred since last
arming are displayed. LEDs 1- 7 display the information from which zones the alarm was
activated. LED 8 indicates that alarm has been triggered from the source other than input
zone. To clear the alarms memory, press
. To exit without clearing the alarms memory,
press
.
Alarm source types:
1 – Sabotage of zone 1
2 – Sabotage of zone 2
3 – Sabotage of zone 3
4 – Sabotage of zone 4
5 – Sabotage of zone 5
6 – Sabotage of zone 6
7 – Sabotage of zone 7
8 – Other alarm
If LED 8 is active (ie. blinks or on), pressing
displays the alarm source type. After pressing
the button corresponding to active LED, the detailed information about the alarm source within
selected type is displayed. Anytime
is pressed, contents of the main level of alarms