CPX200N ALARM CONTROL UNIT – INSTALLER MANUAL
62 / 106
8.3.2.6.
Timer
In this section, you can set the parameters of automatic arming and disarming the
partition.
You can set the time for arming/disarming and you can independently turn on and off
each time. By clicking the check box, located on the left side of the time field, you
can activate/deactivate the time. If auto-arming/disarming is off, the time field is
grayed out.
When the partition is automatically armed / disarmed, to the monitoring station is
sent a report that was done by the user with the number 253.
At the time of auto-arming, exit time is starting. During the exit time, the user may at
any time to stop arming with the code. Then the system will not be armed.
If there is a fault in the system, they not prevent arming (like remote control and
remote command).
For each input line is available „Interlocking after time for exit” option. If this option
is active, in the case of arming with violated zone, after time for exit, will be
generated event about blocked zone. Zone blocking will continue until partition
disarming (see item 8.3.1.3. Interlocking).
When set to the same time arming and disarming, the system will first be disarmed
and then immediately armed.
If the time in the device is set forward (eg. when the time is changed to Daylight
saving time), and arming or disarming time is in the period which has been ommited,
then the hour will be not used. Eg. If the auto-arming time is set to 2:30, and time
was changed forward from 2:00 to 3:00, the control panel will not arm.
Times of arming and disarming can also configure by remote command via GPRS or
SMS.
NOTE: To use the auto-arming/disarming function, you should do
a firmware upgrade to version 1.1.1 or higher, then read and
write the configuration of the device using “GPRS transmitters
configurator” program in version 1.3.45.023 or higher.