25
device is not connected to the server and it gathers in its memory the events to be
sent.
Note:
However, during the charging process, the Active Track Basic+ device placed in the
charging cradle maintains constant communication with the define server.
7.2.3.1.2.1.
SMS command support
This option determines the device's working mode as follows:
if the SMS command support is enabled, the device is in the normal power saving
mode,
if the SMS command support is disabled the device is in the ultra power saving
mode.
The differences between operation modes of the device with
enabled
(column
A
) and
disabled
(column
B
) "SMS command support" option.
Working mode
A
B
Working time between battery charging
about 10 days
about 60 days
SMS command and CSD support in sleep mode
YES
NO
Accelerometer support (Mandown/Tilt/Shock)
YES
NO
Device status indication, including battery low
indication, in sleep mode
YES
NO
Resetting/switching off the device in sleep
mode
YES
NO
Immediate sending of "Panic" message
YES
YES
Switching to the programming mode
after inserting the
programming cable
after inserting the
programming cable and
pressing the button
7.2.3.1.2.2.
Server connection period when communication successfull
In this field, you should define how often the device is to initiate a connection with the
server in order to send the events stored in the device's memory. The format of the
parameter is hours:minutes; for example, if the setting is 04:45, the device will
connect with the server after 4 hours and 45 minutes. The minimum value that can be
set is 02:00 (2 hours), the maximum value is 23:59 (23 hours and 59 minutes).
7.2.3.1.2.3.
Server connection period when communication failuire
This parameter is used when the device has failed to establish a connection with the
server in the scheduled time (see chapter 7.2.3.1.2.2). The parameter in this field
defines the period of time after which the device should start a new connection, after
the last unsuccessful connection.
7.2.3.1.3.
Mobile data transfer
In the Active Track Basic+ device, you can define parameters for: