17
GSMWDT=t
Sets GSM link control, defines time between lost of GSM connection and reset of
GSM modem.
t
- time period [in minutes, range: 5 - 999]
To disable this function
t
must be an empty string.
GETCFG
Gets primary communication parameters of device in form: SERVER PORT APN UN
PW SMS TPERIOD
KILL
Sending this command remotely resets the device.
Example of SMS configuration text message (access code is 1111, skip quotes):
"1111
APN=PGuard.gprs
UN=PGuard
PW=PGuard_pass
SERVER=gprs.com
PORT=6670 DT=05/12/15,13:04 TPERIOD=5"
Note:
Names of programmed parameters (e.g. SERVER) must be in upper-case letters
(see example above).
After changing configuration of Active Track, device must be restarted with
KILL
command.
7.2.
Configuration program
GPRS transmitters configurator
program should be downloaded from
http://www.ebs.pl website (login:
ebs, password: ebs). After downloading and
opening the downloaded file, the installation process will start, during which you
should choose the installation language, enter data, define the location of the program
components (default location is C:\Program Files\EBS\) and create the shortcuts to the
program (on the desktop or on the quick launch bar).
If you have a SIM card with a pre-programmed PIN code other than 1111, you
should first configure the device using the Configurator by entering the pre-
programmed PIN code to the card and only then insert the SIM card into the device.
Otherwise, the card may be blocked (incompatibility of PIN codes).
If you have a SIM card with a disabled PIN code or the PIN code is 1111, you
can insert the SIM card into the device at any time.
7.2.1.
Computer – requirements
Minimum requirements for computer system where configuration software is to be
installed:
Hardware:
Processor 1GHz, 32-bit (x86) or 64-bit (x64),
1 GB RAM (for 32-bit) or 2 GB RAM (for 64-bit),
4,5 GB HDD,
AGP3 programming adapter and LX-PROG programming cable (for local
programming).