MIRU S26PRO
EN
38
www.eberg.eu
»
Check that the correct operating mode and temperature are set.
»
Set the operation mode and temperature as required.
»
Check if a pipe to discharge warm air outside the room is installed.
»
Install a pipe to exhaust the warm air outside the room.
Water leak
»
Water may have spilled out when the machine was moved.
»
Empty the water tank before moving the machine.
»
Make sure the drain hose is not broken or kinked.
»
Straighten the hose to remove any kinks. Replace the drain hose if you find it broken and leaking.
Excessive noise
»
Check that the device is set up correctly.
»
Place the device on a level, hard surface.
»
Check that there are no loose, improperly installed parts in the device (e.g. incorrectly
installed warm air exhaust pipe).
»
Install loose elements securely.
»
The sound of running water.
»
The noise is from the flowing refrigerant. This is normal.
Below is an explanation of error codes that may appear on the display of the device.
Error codes
E0:
»
Communication error between main PCB and display PCB.
»
Check for possible damage to the display PCB wiring harness.
E1:
»
Ambient temperature sensor failure.
»
Check the connection or replace it. Clean or replace the temperature sensor.
E2:
»
Coil temperature sensor failure.
»
Check the connection or replace it. Clean or replace the temperature sensor.
Ft:
»
High condensate level alarm.
»
Empty the drip tray by removing the drain plug.