For more information visit:
www.EatonElectrical.com
Control commands for EZ700
MN05013001E
52
Counters: C1 – C16
The following commands are used to read the logic state of
the individual counters C1 – C16.
Telegram structure
Table 11: Byte 5 to 6: Data 1 to 2
Byte
Meaning
Value (hex), sent by
Master
Slave
0
Toggle byte
J
page 44
1
Command: Read
88
–
Response:
Read successful
–
C2
Command
rejected
–
C0
1
2
Len
01
01
3
Type
EE
EE
4
Index
00
00
5
Data 1 (Low Byte)
00
J
Table 20
6
Data 2 (Low Byte)
00
J
Table 20
7 – 8
Data 3 – 4
00
00
1) Possible causes
J
page 91
Data 1 Bit 7
6
5
4
3
2
1
0
C1
0/1
C2
0/1
...
...
C8
0/1
Data 2 Bit 7
6
5
4
3
2
1
0
C9
0/1
C10
0/1
...
...
C16
0/1
Содержание PROFIBUS-DP EZ204-DP
Страница 2: ......
Страница 9: ...For more information visit www EatonElectrical com MN05013001E 5 Glossary 193 Index 201 ...
Страница 10: ......
Страница 20: ......
Страница 28: ......
Страница 38: ......
Страница 184: ......
Страница 196: ......
Страница 204: ......
Страница 210: ......
Страница 211: ......