For more information visit:
www.EatonElectrical.com
Control commands for EZ700
MN05013001E
90
Table 40: Index 00 – Parameters
Example:
Data 1 (Byte 5) = 0x03
Meaning:
The values of the WH.. 7-day time switch from channel A and
B appear in the parameter menu.
Table 41: Index 01 – Control byte
Channel A, Index 11/12/13
Index 0x11 channel A Weekday on/off
Data 1 (Byte 5) – Weekday on
Data 2 (Byte 6) – Weekday off
0x01 = Sunday ... 0x07 = Saturday
The 16-bit value equals 0x00 if the channel is not used.
Index 0x12 – On time (2 Byte)
Index 0x13 – Off time (2 Byte)
Data 1 (Byte 5) – Hour
Data 2 (Byte 6) – Minute
Example: On time at 13:43 p.m.
Data 1 = 0x0D
Data 2 = 0x2B
Meaning
Bit 7
6
5
4
3
2
1
0
Appears in the parameter menu
Channel A
0/1
Channel B
0/1
Channel C
0/1
Channel D
0/1
Unused bits
–
–
–
–
Data 1
Bit 7
6
5
4
3
2
1
0
FB output
–
–
–
–
–
–
–
Q1
1
1) Status 1, if the count condition is fulfilled.