58
5. Parameter Description
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
Group
No.
Name
Group
No.
Name
06-46
P.742
E3
06-64
P.760
E1 alarm (days/hours)
06-47
P.743
E4
06-65
P.761
E1 alarm (minutes/seconds)
06-48
P.744
E5
06-70
P.766
E2 alarm output frequency
06-49
P.745
E6
06-71
P.767
E2 alarm output current
06-50
P.746
E7
06-72
P.768
E2 alarm output voltage
06-51
P.747
E8
06-73
P.769
E2 alarm the temperature rising accumula-
tion rate
06-52
P.748
E9
06-53
P.749
E10
06-74
P.770
E2 alarm PN voltage
06-54
P.750
E11
06-75
P.771
E2 alarm the time of inverter has run
06-55
P.751
E12
06-76
P.772
E2 alarm inverter operation status code
06-56
P.752
E1 alarm output frequency
06-77
P.773
E2 alarm (years/months)
06-57
P.753
E1 alarm output current
06-78
P.774
E2 alarm (days/hours)
06-58
P.754
E1 alarm output voltage
06-79
P.775
E2 alarm (minutes/seconds)
06-59
P.755
E1 alarm the temperature rising
accumulation rate
07-17
P.802
CAN open communication status
07-18
P.803
CAN open control status
06-60
P.756
E1 alarm PN voltage
09-13
P.124
Expansion card version
06-61
P.757
E1 alarm the time of inverter has run
14-20
P.618
Current value of curling radius
06-62
P.758
E1 alarm inverter operation status code
14-32
P.630
Actual line speed
06-63
P.759
E1 alarm(years/months)
Password protection
•
Registering a password
1. Write a number (2~65535) in 00-05as a password, password protection takes effect immediately;
2. After registering a password,00-05=1;
•
Unlocking password protection
1. Write the correct password in 00-04, and then password protection will be unlocked;
2. After unlocking the password, 00-04=0, 00-05=1;
3. If turn the inverter power off and then turn on, it will still restore to the password protection status.
•
Password all clear
1. Write the correct password in 00-04 to unlock the password protection;
2. Write 0 in 00-05, password will be all cleared.
ote:
N
Please keep the password properly. Bring the inverter to the factory for decryption if the password is forgotten.
5.1.4 Monitoring function
• The item to be displayed on the parameter unitcan beselected.
Parameter
Name
Factory
Value
Setting Range
Content
00-06
P.11
0
Parameter unit monitoring
selection
1
X0
When the inverter starts, the parameter unit enters the
monitoring mode automatically, and the screen displays
the output frequency.
X1
When the inverter starts, the screen of the parameter
unit displays the target frequency.