196
5. Parameter Description
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
5.10 PG feedback parameter group 09
Group
Parameter
Number
Name
Setting Range
Factory
Value
User
settings
09-00
P.349
PG type selection
0: ABZ
0
1: ABZ (Synchronous motor decicated)
2: Resolver 1x Synchronous motor standard encoder
3: ABZ/UVW Synchronous motor standard encoder
09-01
P.350
Number 1 of the encoder pulses
0~20000
1024
09-02
P.351
Encoder input mode setup 1
0: No function
0
1: Phase A/B pulse train, Phase A is 90° ahead of Phase B
and is forward rotation.
2: Phase A/B pulse train, Phase B is 90° ahead of Phase A
and is forward rotation.
3: Phase A is a pulse train. Phase B is a direction sign. L is
reverse rotation and H is forward rotation.
4: Phase A is a pulse train. Phase B is a direction sign. L is
forward rotation and H is reverse rotation.
09-03
P.352
PG abnormality detection time
0~100.0s
1.0s
09-04
P.353
Over-speed detection frequency
0~30.00Hz
4.00Hz
09-05
P.354
Over-speed detection time
0~100.0s
1.0s
09-06
P.355
Number 2 of the encoder pulses
0~20000
2500
09-07
P.356
Encoder input mode 2
0:No function
0
1: Phase A/B pulse train, Phase A is 90° ahead of Phase B
and is forward rotation.
2:Phase A/B pulse train, Phase B is 90° ahead of Phase A
and is forward rotation.
3: Phase A is a pulse train. Phase B is a direction sign. L is
reverse rotation and H is forward rotation.
4: Phase A is a pulse train. Phase B is a direction sign. L is
forward rotation and H is reverse rotation.
09-08
P.357
Dividing frequency output setting
1~255
1
09-09
P.358
Dividing frequency filter coefficient 0~255
0
09-10
P.359
Electronic gear ratio
0~300.00
1.00
09-11
P.360
Prevent reverse rotation detection
pulse number
0~65535
0
09-12
P.361
Rse reverotation detection number 0~65535
0
09-13
P.124
Expansion card version
Read
Read
09-14
P.363
Phase Z adjust margin
0.0°Do not adjust
15.0°
0.1°~360.0°: Phase Z impulse adjust
09-15
P.364
Phase Z DV1/DV2 alarm-enabled
0: Phase Z DV1/DV2 alarm is not valid
1
1: Phase Z DV1/DV2 alarm is valid
09-16
P.386
DXF-ENC-302 Hardware break line
detection
0: Break line detection is invalid
1
1: Break line detection is effective