53
5. Parameter Description
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
5.1.2 Parameter restoration
• Restore the parameters to the default values.
Parameter restoration
1: 00-02 is set to1, and the screen will display
after writing, the abnormal record will be erased, 00-02 is
restoered to 0.
2: 00-02 is set to 1, and the screen will display
, the inverter will be reset.00-02 is restoered to 0.After resetting
the inverter, the values of the two relays, “electronic thermal relay” and “IGBT module thermal relay”will be set to zero.
3: 00-02is set to3, and the screen will display
, all the parameters will be restored to the default values except
the parameters in the
table 1
below.After parameters are restored, 00-02 is restored to0.
Exception
The parameters in
table 1
below will not be restored to the default values:
Parameter
Name
Factory
Value
Setting Range
Content
00-02
P.996
~
P.999
Parameter restoration
0
0
No function.
1
Alarm history clear (P.996=1)
2
Inverter reset (P.997=1)
3
Restoring all parameters to default values (P.998=1)
4
Restoring some parameters to default values1 (P.999=1)
5
Restoring some parameters to default values2 (P.999=2)
6
Restoring some parameters to default values3 (P.999=3)
Group
No.
Name
Group
No.
Name
00-00
P.90
The inverter model
06-58
P.754
E1 alarm output voltage
00-01
P.188
Firmware version
06-59
P.755
E1 alarm the temperature rising
accumulation rate
00-24
P.189
50Hz/60Hz switch selection
01-08
P.21
Accelerate/Decelerate time increments
06-60
P.756
E1 alarm PN voltage
06-27
P.292
Accumulative motor operation time
(minutes)
06-61
P.757
E1 alarm the time of the inverter has run
06-62
P.758
E1 alarm the inverter operation status code
06-28
P.293
Accumulative motor operation time (days)
06-63
P.759
E1 alarm (years/months)
06-29
P.296
Accumulative motor power time (minutes)
06-64
P.760
E1 alarm (days/hours)
06-30
P.297
Accumulative motor power time (days)
06-65
P.761
E1 alarm (minutes/seconds)
06-44
P.740
E1
06-70
P.766
E2 alarm output frequency
06-45
P.741
E2
06-71
P.767
E2 alarm output current
06-46
P.742
E3
06-72
P.768
E2 alarm output voltage
06-47
P.743
E4
06-73
P.769
E2 alarm the temperature rising
accumulation rate
06-48
P.744
E5
06-49
P.745
E6
06-74
P.770
E2 alarm PN voltage
06-50
P.746
E7
06-75
P.771
E2 alarm the time of inverter has run
06-51
P.747
E8
06-76
P.772
E2 alarm the inverter operation status code
06-52
P.748
E9
06-77
P.773
E2 alarm (years/months)
06-53
P.749
E10
06-78
P.774
E2 alarm (days/hours)
06-54
P.750
E11
06-79
P.775
E2 alarm (minutes/seconds)
06-55
P.751
E12
09-13
P.124
Expansion card version
06-56
P.752
E1 alarm output frequency
13-02
P.285
Low frequency vibration inhibition factor
06-57
P.753
E1 alarm output current
13-03
P.286
High frequency vibration inhibition factor