43
4. Primary Operation
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
4.3 Basic operation procedures for different modes
4.3.1 Basic operation procedures for PU mode (00-16(P.79)=0 or 1)
4.3.2 Basic operation procedures for external mode (00-16(P.79)=0 or 2)
Step
Description
1
• Change the operation mode to PU mode, and indicating lamp
PU
will light up.
ote:
N
1. When 00-16(P.79) =0, the inverter will first go into the external mode after the power is switched on or the inverter is reset.
2. For selecting and switching the operation mode, please refer to Section 4.2.
2
• Enter into the frequency setting mode and write the target frequency into memory.
ote:
N
For detailed setting procedures, please refer to Section 4.2.4.
3
• Press
FWD
or
REV
to run the motor. At this point, indicating lamp
FWD
or
REV
will light up, indicating that the motor is running.
The DXF-KEY-LED parameter unit will automatically go into the monitor mode and display the current stable output frequency.
ote:
N
1. For detailed operation flow for the monitoring mode, please refer to Section 4.2.3.
2. While the motor is running, the user can enter into the frequency setting mode to change the target frequency for regulating the motor
speed.
4
• Press
RESET
STOP
and the motor will begin to decelerate until it comes to a full stop.
• Indicating lamp
FWD
or
REV
will not turn off until the inverter stops the output voltage.
Step
Description
1
• Change the operation mode to external mode, the screen will display
and indicating lamp
EXT
will light up.
ote:
N
1.When00-16(P.79) =0, after the power is switched on or the inverter is reset, press
MODE
to switch to operation mode, the inverter willfirst
go into the external mode, and then use
or
>
>
to switch to PU mode.
2. When 00-16(P.79) =2, external mode will be the default for the inverter.
3. For selecting and switching the operation mode, please refer to Section 4.2.
2
• The target frequency is set by external terminals (the default priority is from high to low):
• If the programmable operating mode is chosen, please refer to Section 5.4.1Function selection of digital input and 5.5.2Programmed
operation mode.
• If the target frequency is set by multi-speed stage levels, please refer to 04-00(P.4) in Chapter 5.
• If the target frequency is set by the input signal of terminal A2/B2 on PG board, please refer to 09-07 (P.356) in Chapter 5.
• If the target frequency is set by PWM input pulse, please refer to Chapter 5.4.1.
• If the target frequency is set by the input signal across terminal AI1, please refer to 02-09 (P.38) in Chapter 5.
• If the target frequency is set by the input signal across terminal AI3, please refer to 02-21 (P.39) in Chapter 5.
• If the target frequency is set by the input signal across terminal AI2, please refer to 02-30 (P.508) in Chapter 5.
• If the target frequency is set by the high-speed pulse input across terminal DIH, please refer to Chapter 5.3.8.
3
• Turn on STF or STR to run the motor.
• At this point, indicating lamp
FWD
or
REV
will light up, indicating that the motor is running.
ote:
N
1. For setting up the starting terminals STF and STR, please refer to 00-15(P.78) in Chapter 5.1.8 and 5.4.1Function selection of digital input.
2. For detailed operation flow for the monitor mode, please refer to Section 4.2.3.
3. If programmed operation mode is chosen, then STF and STR will become the starting signal and the pause signal, respectively, instead of
being the Run Forward or Run Reverse terminals.
4
• Turn off STF or STR to decelerate the motor until it comes to a full stop.
• Indicating lamp
FWD
or
REV
will not turn off until the inverter stops the output voltage.
Содержание PowerXL DF1 Series
Страница 1: ...User Manual Effective February 2020 PowerXL DF1 Series VFD...
Страница 2: ......