142
5. Parameter Description
Eaton Electric General Inverters DF1 Series
UMXXXXXXXXE February 2020 www.eaton.com
The second motor parameter
•
When 00-22
≠
99999, RT signal is ON, the second motor parameters 05-22~05-38 are valid, please refer to Section
5.2.10 for the second function parameter.
•
For the usage of the second motor parameter, please refer to 05-01~05-17 motor parameter setting.
Parameter
Name
Factory
Value
Setting Range
Content
05-31
P.341
The second motor (IM)
leakage inductance
99999
0~6500.0mH
45K/55KF and types below
0~650.00mH
55K/75KF and types above
99999
Not selected.
05-32
P.342
The second motor (IM)
mutual inductance
99999
0~6500.0mH
45K/55KF and types below
0~650.00mH
55K/75KF and types above
99999
Not selected.
05-33
P.343
The second motor (PM)
stator resistance
99999
0~65000m
Ω
:
45K/55KF and types below
0~650.00m
Ω
55K/75KF and types above
99999
Not selected.
05-34
P.344
The second motor (PM)
d-axis inductance
99999
0~650.00mH
According to type
99999
Not selected.
05-35
P.345
The second motor (PM)
q-axis inductance
99999
0~650.00mH
According to type
99999
Not selected.
05-36
P.346
The second motor (PM)
Back-EMF coefficient
99999
0~6500.0V/krpm
According to type
99999
Not selected.
05-37
P.347
The second motor (PM)
PhaseZ origin pulse
compensation
99999
0~359.9°
---
99999
Not selected.
05-38
P.348
The second motor rotation
inertia
99999
0~6.5000kg.m
2
5.5K/7.5KF and types below
0~65.000kg.m
2
Types from 7.5K/11KF to 90K/110KF
0~650.00kg.m
2
110K/132KF and types above
99999
Not selected.