Technical Data
A-2
MVX9000 User Manual
Technical Data
Technical Data
Table A-1: MVX9000 115V Specifications
Voltage Class
115V Series
Model Number MVX_ _ _AO-1
F25
F50
001
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
Max. Applicable Motor Output (hp)
0.25
0.5
1
Output
Rating
Rated Output
Capacity (kVA)
0.6
1.0
1.6
Rated Output Current (A)
1.6
2.5
4.2
Max. Output Voltage (V)
Proportional to twice the input voltage
Rated Frequency (Hz)
0.1 to 400 Hz
Input Rating
Rated Voltage
90 to 132V AC
Frequency Tolerance
50/60 Hz ± 5%
1-phase Rated Input
Current
6
9
16
Control
Characteristics
Control System
SPWM (Sinusoidal Pulse Width Modulation)
Output Frequency
Resolution
0.1 Hz
Overload Endurance
150% of rated current for 1 minute
Acceleration/
Deceleration Time
0.01 to 600.00 seconds
Torque Characteristics
Including the auto-torque, auto-slip compensation; starting
torque can be 150% at 1 Hz in vector, 3 Hz in V/F
V/F Pattern
Adjustable V/F pattern or sensorless vector
Stall Prevention Level
Set to percentage of rated current
Operating
Characteristics
Frequency
Setting
Keypad
Set by UP, DOWN keys or potentiomenter
External
Signal
Potentiometer-5 kW/0.5W, 0 to +10V DC or 0 to +5V
(Input impedance 47 kW), RS-485 interface, 4 to 20 mA
(Input impedance 250
Ω
), 1 to 7 step speeds, PID feedback
Operation
Setting
Signal
Keypad
Set by START, STOP, RIGHT and LEFT keys
External
Signal
FWD/STOP, REV/STOP (RUN/STOP, FWD/REV),
3-wire control, serial communication
Digital Input Signal
Multi-step selections 1 to 7, Jog, acceleration/deceleration
inhibit, first/second acceleration/deceleration switch, counter,
External BB (Pause), PLC operation. Terminals have 5V
potential and must be brought to DC common to enable
(Sinking).
Digital Output Indication
Operating, Up to frequency, Desired frequency, Non-zero B.B.,
Abnormal indication, Local/Remote indication, PLC, Low
Voltage.
Analog Output Signal
Analog frequency/current signal output.
Other Functions
AVR, S-Curve, Over-Voltage, Over-Current stall prevention,
Fault records checking, Carrier Frequency adjustable,
DC injection braking, Momentary power loss restart,
Frequency limit setting, Parameter lock/reset,
Frequency input operation method selection,
Reverse run inhibit, etc.
Protection
Self-testing, Over-voltage, Over-current,
Under-voltage, Overload, Overheating, External Fault,
Ground Fault, I
2
t.
Cooling Systems
Forced air-cooling
Содержание MVX9000 Series
Страница 2: ......
Страница 4: ...ii MVX9000 User Manual This page intentionally left blank ...
Страница 16: ...xiv MVX9000 User Manual This page intentionally left blank ...
Страница 124: ...Group 90 Communications 5 76 MVX9000 User Manual Descriptions of Parameter Settings This page intentionally left blank ...
Страница 133: ...MVX9000 User Manual A 1 Technical Data Appendix A Inside this chapter Technical Data Technical Data A 2 ...
Страница 139: ...MVX9000 User Manual B 1 Parameter Tables Appendix B Inside this chapter Parameter Tables MVX9000 Parameter Listing B 2 ...
Страница 168: ...Extension Input Output P N MVXEIO C 14 MVX9000 User Manual Accessories This page intentionally left blank ...
Страница 169: ...MVX9000 User Manual D 1 Dimensions Appendix D Inside this chapter Dimensions Digital Keypad D 2 Drives D 4 ...
Страница 174: ...D 6 MVX9000 User Manual Dimensions This page intentionally left blank ...
Страница 178: ...E 4 MVX9000 User Manual Declaration of Conformity This page intentionally left blank ...
Страница 179: ......