Menvier40/100
Technical Specification
Page 39
Outputs
Panel: O/P 1
Voltage free, single pole relay
contacts rated 24VDC @ 1A.
Panel:
O/P 2 - 3
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/P 1-
16
Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS 1
(loudspeaker)
Min impedance 16 Ohm per
output, current consumption =
280mA in alarm.
Expander:
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited by
the amount available from the
power supply driving the
expander.
KEY-KPZ01
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active, 500mA max.
Sounder Volume Levels (at 1m)
i-kp01 (at max volume)
70dB
Expander sounders
70dB
Expander 16 Ohm loudspeaker
93dB
Fuses
The control unit has a replaceable T250mA mains
fuse.
Electrical Safety
Conforms to EN60950-1.
Other
If you wish to connect the control unit to a PC
using either the Ethernet or the USB port then
make sure that the cables have the following
specifications:
Ethernet
Cat5e patch cable, RJ45 male
plugs at each end, suitable for
10/100Base-T.
USB
Mini-B plug for control unit end,
USB-A for PC end. Max length
3m.
Radio Expander and Keypads
Radio
Operating frequency
868.6625MHz Narrowband.
EN 300 220-3.
EN 300 330-2
Transmitter
range
The range of the transmitters
compatible with this control unit
depends on the environment in
which they are installed. As a
guideline, most transmitters will
work up 200m range in free
space conditions.
Compliance Statements
The Menvier40 and Menvier100 are compliant
with EN50130-5 environmental class II.
The Menvier40 and Menvier100 are suitable for
use in systems designed to comply with PD 6662:
2010 at grade 3.
When installed correctly the Menvier40 and
Menvier100 are capable of compliance with
EN50131 at Grade 3.
To maintain Grade 3 the Menvier40 and
Menvier100 must be fitted with a communicator of
level ATS4 or above.
When fitted with radio devices the Menvier40 and
Menvier100 are capable of compliance with
EN50131 at Grade 2.
The i-sd02 is compliant with EN50136-1 as an
ATS2 communicator.
The i-sd02 may be used as a supplementary
communicator at Grade 3.
At Grade 2 the i-sd02 provides a compliant
communicator for the Menvier40 and Menvier100
provided that:
a) It is installed in accordance with the
installation instructions.
b) The connected PSTN is functioning normally.
When fitted with an i-sd02 the control unit
provides options A, B and C at Grade 2 as noted
in Table 10 of EN50131-1:2006+A1:2009.
If the installer selects a non-compliant
configuration then they must remove or adjust
compliance labelling
Third party testing carried out by Anpi.