Technical Specification
Menvier40/100
Page 38
Security
Security Grade
Grade 2 or 3
Radio detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
access codes
100 plus one installer
Access code
differs
10,000 differs with 4 digit
codes.
1,000,000 differs with six digit
codes.
All digits may be any number 0
to 9.
Code blocking
Blocked for 90s after four
incorrect codes in series.
Proximity tag
differs
4,294,967,296 (2
32
)
Power Supply
This product complies with the requirements of EN50131-6
Type A power supply at Grade 3 and environmental class 2.
Power supply type
A
Mains power supply
requirements
10%/-15%,
170mA max, 50Hz.
Total power supply
capacity:
1.5A
(of which 750mA is used
for battery recharge and
750mA is available for
powering the system).
12V Aux supply*:
500mA max
12V Bell supply
500mA max
Comms power
supply*:
400mA max
12V Expander Bus*:
400mA max
LS connectors
280mA in alarm.
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.
EN50131-6 ratings
The control unit provides space for one 17Ah
battery.
Under EN50131-6 for Security Grade 3
installations the required battery standby time is
60 hours. However, with an ATS4 communicator
fitted the requirement drops to 30 hours.
This means that all the devices powered by the
backup battery, including the control unit and at
least one keypad, should together draw no more
in total than an average of 570mA over a 30 hour
standby time. Note that for Security Grade 3 the
control unit must use a plug-by communicator,
which may have its own power supply.
For Security Grade 2 the required battery standby
time is 12 hours. However, the total average
current available over 12 hours from the 17Ah
battery is limited by the power supply to 750mA.
(The current is limited to 750mA because when
mains is present the 1.5A power supply reserves
750mA to recharge batteries, leaving 750mA
available to supply the system.)
The table below shows the current consumption of
the control unit and each device that can be fitted
to it.
CIE power
requirement:
120mA min.
200mA max
i-kp01 power
requirement:
30mA (normal/idle)
45mA (backlight low)
65mA (backlight high)
KEY-
KPZ01/KP01/K01
power requirement
35mA backlight OFF,
internal prox reader only.
65mA max backlight ON,
external prox reader
connected
Wired Expander
requirement
20mA max quiescent.
300mA in alarm if
sounder connected.
Radio Expander
requirement
40mA max quiescent
320mA in alarm if
sounder connected.
Battery charging
requirement:
750mA per battery
(recharge to 80% within
24 hrs)
Plug-on
Communicator power
requirement:
i-sd02 or i-dig02: 20mA
quiescent
50mA max
Plug-on
Communicator power
requirement
i-gsm02:
150mA quiescent
and max.
Plug-by
Communicator pins
require:
3mA each when active.
10 FSL zones
20mA
5 CCL zones
30mA
12V Bus output
voltage range :
10±0.5V to 13.8V
12V Aux output
voltage range:
10±0.5V to 13.8V
12V Bell output
voltage range
10±0.5V to 13.8V
Max p-to-p ripple
voltage:
0.5V
Standby Battery:
12V, 17Ah sealed lead
acid (not supplied).
‘Low battery’ fault at:
< 12V
Aux power output fault
at:
< 9V
Deep discharge
protection at:
10±0.5V
Overvoltage protection
trigger voltage
15.8±1.0V
Standby time:
See “Power Availability”
on page 10.
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.