9. Press
.
The
keypad sounder gives “deed ah”
confirmation tone and the display shows the
time and date, for example:
The control unit has saved all the changes
you have made.
Step 12. Commission the
System
Install Detectors and Other Peripherals
1. Use the Installer Menu to teach the system
the identity of any radio detectors or other
peripherals. (
You must have a radio expander
already connected and installed on the bus to
do this.
) See the installation instructions
supplied with each detector or peripheral.
Note: When checking signal strength from the
User Menu the minimum acceptable signal
strength from a detector is four units.
When checking the signal strength from the
Installer Menu the minimum acceptable signal
strength from a detector is two units.
Record the reading shown in the Installer Menu
for later inspection.
2. Install detectors and peripherals at their
selected locations.
3. Use the
Installer Menu – Test
(see Chapter
5) option to:
a) carry out a walk test of the detectors.
b) test the operation of any other peripherals.
Program the System
Program the system to suit user requirements.
Page 34 is a summary of the Installer Menu on
the control unit. Please see the
Menvier40/100/300 Engineering Guide
for a more
detailed description.
Note: make sure that you allocate keypads
correctly to wards. For more information see
“Assigning Wired Keypads to Wards” in the
Menvier40/100/300 Engineering Guide
.
Assemble and close the control unit:
a) Fit the lid of the control unit into the back of
the case (see Fig 56).
b) Fit and tighten the lid fixing screw.
NOTE: It is possible, for convenience, to place
links over tamper contacts to inhibit tamper alarm
during installation. Because of this feature make
sure you test all lid tampers before completing
installations, to ensure that no links are left fitted.
Figure 56 Replacing the control unit lid.
Leave the Installer Menu.
The red LEDs should go out, and the rim of
the navigation keys glow green. The system is
now ready to hand over to the user.
Handover to the User
Instruct the user on how to operate the system.
See the
Menvier40/100/300
Administrator’s
Guide
. If necessary, show them how to set the
time and date on the system.