P11.9
601
-
Pulse frequency
6.0
1.5 - 16.0 kHz
Using a high switching frequency can reduce the magnetization
noise in the motor.
The heat dissipation in the inverter (IGBT) increases with higher
switching frequencies.
With motor frequencies < 5 Hz a higher speed stability can be
achieved at low switching frequencies.
Note:
As a protection against thermal overload, MMX reduces the
switching frequency automatically if, for example, too high values
are set and with high ambient temperatures and high load
currents.
Parameter P11.10 = 1 must be set for operation at a constant
pulse frequency.
P11.10
522
-
Pulse frequency, stabilizer (sinusoidal filter)
0
0
Deactivated
1
Activated
Note:
When using a sinusoidal filter, the pulse frequency must be
constant.