04/10 MN04020001Z-EN
Parameter menu (PAR)
107
The run times in the individual program steps must be greater than
the transition times for the subsequent frequency value. Example
as per Figure 94 (Example A):
Acceleration time P6.5 = 3.0 s
Maximum frequency P6.4 = 60 Hz
FF1: P10.2 = 20 Hz
FF2: P10.3 = 40 Hz
The transition time from FF1 to FF2 is one second. Parameter
P10.13 should therefore be set to a value greater than one second.
t
FF
f
D
FF x P6.5
P6.4
P10.13
f
(P10.3 - P10.4) x P6.5
f
(40 Hz - 20 Hz) x 3 s
f
1 s
P6.4
60 Hz
PNU
ID
Access right
RUN
Value
Description
Factory setting
(P1.3)
P10.11
1438
/
Set time for FF0
0
0 - 1000 s
0 s = Fixed frequency FF0 deactivated
(sequence control P10.9)
P10.12
1439
/
Set time for FF1
0
0 - 1000 s
0 s = Fixed frequency FF1 deactivated
(sequence control P10.9)
P10.13
1440
/
Set time for FF2
0
0 - 1000 s
0 s = Fixed frequency FF2 deactivated
(sequence control P10.9)
P10.14
1441
/
Set time for FF3
0
0 - 1000 s
0 s = Fixed frequency FF3 deactivated
(sequence control P10.9)
P10.15
1442
/
Set time for FF4
0
0 - 1000 s
0 s = Fixed frequency FF4 deactivated
(sequence control P10.9)
P10.16
1443
/
Set time for FF5
0
0 - 1000 s
0 s = Fixed frequency FF5 deactivated
(sequence control P10.9)
P10.17
1444
/
Set time for FF6
0
0 - 1000 s
0 s = Fixed frequency FF6 deactivated
(sequence control P10.9)
P10.18
1445
/
Set time for FF7
0
0 - 1000 s
0 s = Fixed frequency FF7 deactivated
(sequence control P10.9)
Содержание M-Max series
Страница 8: ...04 10 MN04020001Z EN 4...
Страница 12: ...04 10 MN04020001Z EN 8...
Страница 58: ...04 10 MN04020001Z EN 54...
Страница 66: ...04 10 MN04020001Z EN 62...
Страница 138: ...04 10 MN04020001Z EN 134...
Страница 150: ...04 10 MN04020001Z EN 146...
Страница 196: ...04 10 MN04020001Z EN 192...