System Options Menu
Page 87
After Entry
This is available for only for UK control units and when
Confirmation Mode
is set to DD243
or BS8243.
Never
The control unit turns alarm confirmation off if the user enters by the entry door (used
for DD243:2004 clauses 6.4.2 and 6.4.4 and BS8243:2010).
1 zone
The control unit starts a confirmed alarm if the intruder activates one or more zones
(not on the entry route) after entering the premises through the final exit zone.
2 zones
The control unit starts a confirmed alarm if an intruder activates two or more zones
(not on the entry route) after entering the premises through the final exit zone (used
for DD243:2004 clauses 6.4.5)
Note:
This option is not available if you have selected
BS8243 for Confirmation Mode.
Entry Keypad Lock
This is available for only for UK control units and when
Confirmation Mode
is set to DD243
or BS8243.
The option determines whether the user can unset the system by entering an access code
after opening the entry door. Select one of the following:
Off
The user can enter an access code at the keypad after the entry door opens (used
for DD243:2004 clause 6.4.4).
On
The user must unset the system by some means other than the keypad, such as a
proximity tag, remote control or key switch (used for DD243:2004 clause 6.4.5 and
BS8243:2010 6.4.5b).
Note:
This option has no effect if the alarm response (for either full set or part set) is
set to Siren or Internal. In those cases, the user will still be able to unset the system
using an access code.
Entry Keypad Lock
is intended for use when the system can
summon a police response.
Sounder On
Unconfirm
When the system is set, the control unit activates the internal sounders when an
unconfirmed alarm occurs.
Confirm
When the system is set, the control unit does not activate the internal sounders until
a confirmed alarm occurs.
Note:
The control unit will not allow you to select
Sounder on
– Confirm
at the same
time as
Siren on
– Unconfirm
.