Page 138
Appendix C: Log Messages
Introduction
This Appendix gives short explanations of the messages that can appear in the control
unit’s log.
Please note that many of the messages refer to specific devices by the bus and device
number. Therefore, it is not possible to show in this list the exact log message that you
may be seeing on any given installation.
The list itself is sorted alphabetically by the text of th
e message. In the column “Event Log
Text” you will see “==” or sometimes “#”. These characters stand in for the zone, user or
device number that the control unit has recorded for the event being logged. In the
“Description” column this is shown as “nn” or “n”. In the first seven messages listed the
characters “$m” stand in for the type of communications module fitted.
Log messages
Event Log Text
Description
$m Alarm Fail
Communicator failed to send
alarm.
$m Email Fail
Control unit failed to send email.
$m Line Fault
Communications line failed.
$m Line Restore
Communications line restored.
$m Modem Fault
Modem failed.
$m Modem Restore
Modem restored.
$m SMS Fail
SMS call failed to get to
destination.
$m Speech Fail
Speech dialler failed to send
alarm.
== A/C Fail Flt
AC mains fail.
== A/C Fail Rst
AC mains restored.
== Aux Fuse Flt
Aux fuse failed.
== Aux Fuse Rst
Aux fuse restored.
== Aux1 O/P Flt
Auxiliary output 1 fault.
== Aux1 O/P Rst
Auxiliary output 1 fault restored.
== Aux2 O/P Flt
Auxiliary output 2 fault.
== Aux2 O/P Rst
Auxiliary output 2 fault restored.
== Batt 1 Rstr
Battery 1 restored.
== Batt 1 Rstr
Battery 1 missing restored.
== Batt 2 Rstr
Battery 2 restored.
== Batt 2 Rstr
Battery 2 missing restored.
== Bus O/P Flt
Bus dc power output fault.
== Bus O/P Rst
Bus dc power output restored.
== Chargr 1 Flt
Battery 1 charger fault.
== Chargr 1 Rst
Battery 1 charger fault restored.
== Chargr 2 Flt
Battery 2 charger fault.
== Chargr 2 Rst
Battery 2 charger fault restored.
== Coms O/P Flt
Plug-by comms output fault.
== Coms O/P Rst
Plug-by comms output fault
restored.
== Ex Keys Rstr
Excess keys (code attempts)
tamper restore
== Load 1 Fail
Battery 1 failed load test.
== Load 1 OK
Battery 1 passed load test.
== Load 2 Fail
Battery 2 failed load test.
== Load 2 OK
Battery 2 passed load test.
== Low Batt 1
Battery 1 low.
== Low Batt 2
Battery 2 low.
== Low Voltage
PSU reports low voltage.
== Miss Batt 1
Battery 1 missing.
== Miss Batt 2
Battery 2 missing.
== RF OK
Radio signal restored for device nn
== RF Warning
Radio signal lost for 20 min for
device nn
== Superv Fail
Radio signal fail for 2 hours for
device nn
== Superv Rstr
Radio signal restored for device nn
== Sys Volt Flt
System voltage fault.
== Sys Volt Rst
System voltage fault restored.
== Voltage OK
Voltage OK.
24hr Z=== Alarm
24 hour alarm on zone n.
24hr Z=== Restore
24 hour alarm on zone n restored.
4K4 Fault Z==
Fault resistor active on zone nn
4K4 Rstr Z==
Fault resistor restored on zone nn
A/C Fail Ptn ##
A zone of type "AC Fail" was
triggered in the specified partition.
A/C Fail
AC mains failed and was
communicated.
A/C Restore
AC mains was restored.
A/C Rstr Ptn ##
A zone of type "AC Fail" was
restored in the specified partition.
Al. Conf ==RKBS
Confirmed alarm with tamper on
nn radio keypad base station.
Alarm Abort U--
Alarm aborted by user.
Alarm Conf ==ER
Alarm has been confirmed by a
missing external prox reader on
keypad nn.
Alarm Conf ==IS
Confirmed alarm with tamper on
nn Internal Radio Sounder.
Alarm Conf Aux #
Confirmed alarm with tamper on
Aux nn.
Alarm Conf Bell #
Confirmed alarm with tamper on
Bell nn.
Alarm Conf SMS
Confirmed alarm with SMS Control
user code tamper.
Alarm Conf Websvr
An alarm was confirmed by a user
on the web browser interface
typing the password incorrectly
more than four times in a row,
Alarm Conf. ==
Confirmed alarm with tamper on
keypad.