Getting Started
Page 21
8.
Select the wiring type you intend to use for wired zones (page 7):
This determines the default wiring type for the control unit and any attached bus
devices, such as wired expanders. You can change the control unit's wiring type
through
Installer menu
– System Options
, or specify a different wiring type for a bus
device through the device's edit menu (e.g.
Installer menu
– Detectors/Devices –
Wired Expander
– Edit Expander
).
Note:
If you are using an ADP-10CC board (to provide ten on-board 4-wire CC zones
instead of ten FSL zones), select 2-wire FSL 2k2/4k7 as the wiring type.
9.
Specify an installer code:
When prompted, confirm the code.
DO NOT FORGET THIS CODE!
10. You will see one of the following:
If the lid of the control unit is closed, you will see the standby screen. For
example:
If the lid of the control unit is open, you will see:
11. If the standby screen is displayed, enter the Installer code to enter the Installer menu.
Otherwise, if the "Panel lid open" message is displayed, press
to access the
Installer menu.
The first option in the menu is displayed:
12. Use the Installer menu to carry out the required configuration tasks, such as to:
Add the other bus devices, if used (page 50).
Program zones.
Configure outputs.
Configure setting options.
13. Exit the Installer menu (page 23).