Test Menu
Page 116
Audible
If the system is unset then the system logs the event. The keypads produce a short
audible tone every minute. Entering a valid access code silences the sounders and
the display indicates a telephone line fault. The system can be set again with the line
fault present.
If the system is set then the control unit logs the event but does not give any tone or
display. The control unit cancels any programmed siren delay if the line is out of
order when an alarm occurs.
Note:
Eaton recommends audible response for line fault.
Silent
If the system is unset then the keypad display indicates a telephone line fault, the
LEDs around the navigation key glow red, and the control unit logs the event. The
system may be set again with the line fault present.
If the system is set then the control unit does not give any indication or tone but does
log the event. The control unit cancels any programmed siren delay if the line is out
of order when an alarm occurs.
Disabled
The control unit does not monitor the telephone line.
Line Fail Delay
Use this option to specify the length of time the control unit waits after detecting a line-fail
fault on a communications path from the control unit before it generates an alert, actives
communications and activates line-fail outputs. You can specify different settings for
Ethernet, plug-by and plug-on module communications.
Note:
The control unit may take a few seconds to recognise a line fail. The actual delay
between line fail and the resulting alert will be slightly longer than the value you specify.
IP Network (Own)
This menu allows you to configure settings related to the Ethernet port of the control unit.
Note:
Remember that changes are not saved until you exit the Installer menu.
Web Server
This controls the availability of the control unit’s built-in web interface.
Status
Set to Enabled to enable the interface.
IP Port Number
This is the port that the control unit uses for the interface. The default is 80.
VKP Instant
This option is available only if
Status
is set to Enabled. Set
VKP Instant
to Enabled to
enable the virtual keypad, known as the Virtual Keypad Instant or VKP Instant. When
enabled, anyone on the network can access the virtual keypad through a web
browser using the url: “https://[panel IP address:4433]/keypad.cgi”. For example,
“http://198.168.0.100:4433/keypad.cgi”.
The virtual keypad allows users to perform the same functions as at a standard
keypad, providing they have a valid access code.
Note:
The browser must have cookies enabled for the virtual keypad to work
correctly.