System Options Menu
Page 84
Quick Omit
Yes
– Allows users to omit a zone that is active while the user is setting the system. The
zone must have the Omittable attribute (see page 47).
No
– Users must use the
Omit
menu to omit a zone that is active before they can set the
system.
User Code Reqd
Yes
– After entering the installer code, the system prompts for a user code before allowing
access to the Installer menu.
No
– You can access the Installer menu simply by keying in the installer code.
Note:
If you select this value, the control unit no longer complies with EN50131. This
value complies with PD6662 only if the user has given written consent.
2 Way Replies
Use this option to decide whether the control unit can send status messages to a two-way
remote control unit (FOB-2W-4B).
2 Way Set Instant
Use this option to specify how a two-way remote control unit (FOB-2W-4B) sets the
system.
Yes
– The partition or system sets instantly when the user operates the FOB-2W-4B.
No
– The partition or system follows the setting mode programmed for it in
Partitions
or
Setting Options
(see page 72).
Duress Enable
Selecting Yes allows master users to assign the Duress user type to users.
A duress code can set and unset the system in the same way as a normal user. However,
each time the code is used, the control unit triggers any output configured as type Duress,
and (if applicable) communicates Duress and Set/Unset events.
Terminated Set
This option is relevant if you are using a KEY-EP external proximity reader connected to a
keypad.
Yes
– Select this if you want to start the setting procedure from a keypad and complete it
at the KEY-EP. You will not be able to start the setting procedure from the KEY-EP.
For this setting, also configure
Partitions
– Exit Mode
(for a partitioned system) or
Setting Options
– Full/Part Set – Exit Mode
to Exit Terminate.
No
– Select this if you want to able to start the setting procedure from the KEY-EP (or from
a keypad). In this case, choose an exit mode such as Timed Set or Instant Set. When
you present the proximity tag to the KEY-EP, the system sets with no further action.
For both settings of Terminated Set, presenting a tag to the KEY-EP when the system is
set immediately unsets the system.