Test Menu
Page 117
The Installer access code can use the virtual keypad only when the system is
completely unset.
VKP Instant
is designed for use on PCs, mobile devices and tablets.
Downloader
You can use this option to specify the port that the control unit uses for Downloader over
IP. The default is 55132.
M2M Interface
This controls the availability of the control unit’s Machine-to-Machine (M2M) interface,
which allows real-time streaming of data to a machine via Ethernet. For further information,
please contact your Area Account Manager.
Status
Set to Enabled to enable the interface.
IP Port Number
This is the port that the control unit uses for the interface. The default is 1895.
IP Address
This specifies the
control unit’s own IP address (e.g. “192.168.000.100”). Press “*” to key
in a dot. Leave the IP address blank if you want a DHCP-assigned address. If you enter an
IP address, also specify the
IP Subnet Mask
,
Gateway IP Address
and
DNS IP Address
.
Note:
Changes take place only after you exit the Installer menu. If you are using DHCP,
use
About Panel
– About Comms – IP Address
to find out the IP address the control unit is
using.
IP Subnet Mask
This option is displayed if
IP Address
specifies a fixed IP address. Enter the subnet mask
(e.g.
“255.255.255.000”).
Gateway IP Address
This option is displayed if
IP Address
specifies a fixed IP address. Enter the IP address of
the router that connects the local network, to the internet (or to a larger network).
DNS IP Address
This option is displayed if
IP Address
specifies a fixed IP address. Enter the IP address of
the DNS server on the network.
Module Ethernet
This menu is available if there is another compatible (e.g. Chiron) module fitted.
IP Address
This specifies the
module’s own IP address (e.g. “192.168.000.001”). Press “*” to key
in a dot. Leave the IP address blank if you want a DHCP-assigned address. If you
enter an IP address, also specify the
IP Subnet Mask
and
Gateway IP Address.
IP Subnet Mask
Enter the subnet mask (e.g. “255.255.255.000”).