60
and then follow the steps shown in Figure 6-10. Connection method for drive test. The test waveforms of each key
device are shown in Table 6-10.
Fig.6-10 The connection of drive test circuit of 10kVA IP/OP board
Table 6-10 The driver test description of 10kVA IP/OP board
Component and its tag number
Waveform
Remark
Charger IGBT
Q23,Q24
High level
+15V±1V
;
Low level
-8V±1V
;
Frequency
40KHz
;
If it is found that the individual IGBT drive wareform is abnormal during the drive test, please re-check
whether the device is replaced, and check whether the corresponding drive module is damaged.
6.2.2 Maintenance of 15kVA IP/OP board
15kVA IP/OP board mainly includes auxiliary power supply, charger, input filter, output filter and mains soft
start circuit. Among them, the fragile components are shown in Table 6-11, and the position of the board is shown
in Fig 6-11.
Table 6-11 The frogile components of 15kVA IP/OP board
Components
Tag Number
Specifications
Alternative
specification
Input/Output Fuse
F1,F3,F5,F8,F10,F12
324-0324030
Battery Fuse
F15,F16
100A/690V
Charger Fuse
F13,F14
10A/250V
Charger IGBT
Q23,Q24
IKW30N65H5
JT050N065WED
Charger Diode
D9,D10,D43,D44
RHRP3060
MM30FU60K
Содержание EA990G5
Страница 4: ...7 1 Boards installation 72 7 2 Preparation before power on 72 7 3 Power on and testing 72...
Страница 9: ...5 Fig 2 5 The rear pannel of 30kVA UPS Tower Fig 2 6 The rear pannel of 10kVA 15kVA 20kVA UPS Rack...
Страница 43: ...39 Fig 5 9 The left side board of 15kVA standard model Tower Fig 5 10 The board of 15kVA model Rack...
Страница 48: ...44 Fig 5 19 The left side board of 30kVA standard model Tower...