4.2.2.2
Switch and Dim
Figure 9
When touch button function selected as “Switch and Dim” touch button can be configured in three
different
ways to control brightness value.
Short Touch
Long touch
Darker(Short Touch Off)
Off (%0)
Decrease, (%XX)
Brighter(Short Touch On)
On(%100)
Increase,(%XX)
Darker/Brighter(Short Touch
Toggle)
Toggle between
Darker/Brighter
Decrease, (%XX) /
Increase,(%XX)
Table 18
%XX values can have different values relative to the “Dimming Type” parameter. “Dimming Type”
parameter allows two different types of dimming functionality “Start Stop” and “Step Wise”.
Dimming - Start Stop Type
When touch button touched (and not released) and touched duration exceeds “Long Touch
Duration” time “Increase, %100” (When button in Brighter mode) or “Decrease, %100” (When
button in Darker mode) dimming level will be send using respective communication object. When
button released “Increase, Break” or “Decrease, Break” value will be send.
Dimming - Step Wise Type
When touch button touched (and not released) and touched duration exceeds “Long Touch Duration”
time, a step value level configured in “Step Value” parameter will be send using respective
communication object. If button mode is “Darker”, “Decrease, % [Step Value]”, else button mode is
“Brighter”, “Increase, % [Step Value]” values will be send. Until button is released same step value will
be send periodically with a time interval defined in “Step Send Interval”.