11
4.2.2
ELBus®
connector sockets to power distribution system (-X51, -X52, -X53, -X54)
1. Data line
ELBus® ELB
2. Supply voltage
ELBus® + 24 V
3. Supply voltage
ELBus® GND
fig. 8: Terminals of the
ELBus
® connectors
X51
COM-1: terminal for first power distribution board SVS201-PWR-xx
Cable length:
max. 2 m
Typically:
H07V-K 1.5 mm
2
Connector 1:
ELBus
® ELB
Data line
Connector 2:
ELBus
®
DC + 24 V
Connector 3:
ELBus
®
GND
X52
COM-2: terminal for second distribution board SVS201-PWR-xx
Cable length:
max. 2 m
Typically:
H07V-K 1.5 mm²
Connector 1:
ELBus
® ELB
Data line
Connector 2:
ELBus
®
DC + 24 V
Connector 3:
ELBus
®
GND
(only with CPC10PN-T4)
X53
COM-3: terminal for third distribution board SVS201-PWR-xx
Cable length:
max. 2 m
Typically:
H07V-K 1.5 mm²
Connector 1:
ELBus
® ELB
Data line
Connector 2:
ELBus
®
DC + 24 V
Connector 3:
ELBus
®
GND
(only with CPC10PN-T4)
X54
COM-4: terminal for fourth distribution board SVS201-PWR-xx
Cable length:
max. 2 m
Typically:
H07V-K 1.5 mm²
Connector 1:
ELBus
® ELB
Data line
Connector 2:
ELBus
®
DC +24 V
Connector 3:
ELBus
®
GND
(only with CPC10PN-T4)
Содержание ControlPlex CPC10PB