Maintenance - 500h
IPL350TD-1EN2.pdf
2012-06-18
Maintenance - 500h
Make sure that ventilation (extraction) is
adequate if the engine is run in poorly ventilated
areas. Risk of carbon monoxide poisoning.
Make sure that ventilation (extraction) is
adequate if the engine is run in poorly ventilated
areas. Risk of carbon monoxide poisoning.
Place the planer on a level surface.
The engine must be switched off during all
checks and adjustments of the planer, unless
otherwise specified.
Place the planer on a level surface.
The engine must be switched off during all
checks and adjustments of the planer, unless
otherwise specified.
Fuel filter - Replacement
Fig. Fuel filter
The fuel filter is located behind the right-hand engine
compartment cover and must be replaced every 500 h.
Release the fuel filter and clean the contact surface.
Lubricate the seal on the new filter.
Tighten the filter by hand.
Bleed the filter, see chapter Fuel filter - Bleeding the
filter.