Maintenance - 250h
IPL350TD-1EN2.pdf
2012-06-18
3
2
Fig. Air cleaner
1. Clips
2. Cover
3. Main filter
1
Clean the air cleaner if necessary, see section Air
cleaner - Cleaning.
When replacing the main filter (3), insert a new filter
and refit the air cleaner in the reverse order.
When refitting the cover, make sure that the dust valve
is positioned downwards.
Air cleaner
- Cleaning
Wipe clean the inside of the cover (2) and the filter
housing (5). See the previous illustration.
Wipe clean on both sides of the outlet
pipe.
Outer edge of outlet
pipe.
Inner edge of
outlet pipe.
Wipe also both surfaces for the outlet pipe; see
adjacent figure.
Check that the hose clamps between the filter
housing and the suction hose are tight and that
the hoses are intact. Inspect the entire hose
system, all the way to the engine.
Check that the hose clamps between the filter
housing and the suction hose are tight and that
the hoses are intact. Inspect the entire hose
system, all the way to the engine.