Maintenance – 50h
76
4812273203.pdf
2017-08-25
Fig. Drying filter
1. Sight
glass
2. Filter
holder
Fig. Cab
1. Condenser
element
Air conditioning (Optional) – Drying
filter – Inspection
Park the roller on a level surface, chock the
wheels and the set the Forward/Reverse lever in
the Neutral position.
With the unit in operation, check using the sight glass
(1) that bubbles are not visible on the drying filter.
Make sure the Forward/Reverse lever is
always in the Neutral position.
The filter is located on the top of the rear part of the
cab roof. If bubbles are visible through the sight glass,
this is a sign that the refrigerant level is too low. Stop
the unit to avoid risking damage. Fill up with
refrigerant.
Air conditioning (Optional) – Cleaning
If there is a significant loss of cooling capacity, clean
the condenser element (1) on the rear edge of the cab
roof.