47
Figure 62.
BIN SETUP screen
The across arrow is used to cycle through the bins, the end of the arrow
moving to identify the selected bin. The down arrow is used to cycle down
through the 3 factors, after the third it returns to the top of the list again. The
first factor is the ratio of the gearbox fitted to the motor. Default value is
100:1. The second factor is the maximum motor speed. This is used to
calculate the maximum forward speed that any application rate set into the
system can be achieved. The third factor is the shaft sensor pulses per
revolution. This is used to calculate the shaft speed correctly.
Press ESC to exit the BIN SETUP screen and return to the DRILL SETUP
screen.