25
Pt. No. 67437
Issue 0716
‘Renovator Mk4’
Calibration
(ii) Calibration via ‘SETUP’ MENU continued
9
NOTE: If, when presing the priming switch the motors do
not turn but there are no other errors, it could be that the
previous calibration was wrongly entered. The metering
speed is out of the range of the motor speed.
This can be corrected by manually entering a ‘calibration
factor’ as follows:
(i) Press the ‘INFO’ menu key.
(ii) Select the appropriate bin.
(iii) Press the ‘SETUP’ key.
(iv) Use the up down arrows to select the ‘Cal. factor’
line.
(v) Type 0.500 and hit the ‘ENTER’ key. (You need to
enter the leading zero as the machine will not accept
the ‘.’ as a first character.) Note that although the default
calibration factor for Grass is 0.28 kg/rev resetting to
0.500kg per rev gets the machine working again for
re-calibration.
(vi) Hit the ‘ESC’ key to return to the ‘SETUP’ menu or
hit the ‘MAIN’ key to return to the ‘MAIN’ menu.
(vii) Repeat the calibration process from step 1.