60
Significant variation
with tractor speed
Check for wheel slip
Recalibrate tractor radar
Bin low level
alarm does not
function
Hopper alarm is turned
off
Low sowing speed
Faulty sensor (LED on
rear of sensor is
illuminated when
covered)
Faulty harness
Faulty motor control
module
Turn hopper alarm on
Hopper alarms are only active when sowing
above the minimum forward speed setting,
refer C.1.5.2
Connect sensor from another bin, if
operating correctly, then replace faulty
sensor
Disconnect sensor, if alarm is not activated
then there is a harness fault
Replace motor control module with correct
ID
Bin low level
alarm sounds
continuously
Low theoretical volume
shown on main
operating screen
Low bin level
Faulty sensor
Check bin level and if necessary adjust
product weight in bin or deactivate alarm
by setting low level alarm to 0kg
Bin contents is low, sensor is uncovered
and more product needs to be added or
turn alarm setting to off
Replace sensor with a known working
sensor, if the replacement sensor works the
original sensor is faulty
Priming switch
not functioning
Faulty sensor
Connect another priming switch, if
functioning correctly then original switch is
faulty
Shaft
confirmation
alarm sound
continuously
Magnet ring position
Incorrect setting
Faulty sensor
Check magnet ring is in line with sensor
and adjust if necessary
Check the height of sensor in relation to the
magnet ring and adjust if necessary
Check the shaft sensor PPR setting on the
bin setup screen is 3
Connect another sensor, if functioning
correctly then original sensor is faulty
One motor
control module
is offline
Incorrect bin
configuration
Incorrect motor control
module fitted
Check the bin configuration setup on the PS
console and change if necessary
Check the motor control module
identifications are correct and change
module if required
Содержание MK4 Renovator
Страница 2: ...ii ...
Страница 17: ...15 Pt No 67437 Issue 0716 Renovator Mk4 ...
Страница 29: ...27 Pt No 67437 Issue 0716 Renovator Mk4 Calibration Notes ...
Страница 30: ...28 ...
Страница 34: ......
Страница 36: ...1 ...
Страница 63: ...28 Figure 33 Motor control module offline ...