15
With the desired bin/product selected simply use the key pad to enter the desired
application rate. The digits will flash and pressing ENTER will confirm the rate
entered. Maximum is either 3 digits to 0 decimal places or 1 digit to 1 decimal
place. Resolution will be as follows 0.0 to 9.9 in 0.1 kg steps, 10 – 99 in 1 kg
steps, 100 – 999 in 5kg steps. Values programmed will be rounded to the nearest
acceptable value, i.e. 254 will be 255. It will only be possible to enter a new
application rate if the forward speed is below the minimum forward speed setting.
This rate is then saved against the specific product within the PRODUCT SETUP
screen, refer Figure 3.
When a new product rate has been entered, the MAIN screen shows the maximum
forward speed for 3 seconds or until a Key has been pressed. See Figure 13. The
maximum forward speed shown is the corresponding ground speed when the
motor is at maximum speed. This is based on the product calibration factor.
Figure 13. MAIN screen - max ground speed
Keys F & G are used to change the rate of the product selected. The default step
size is 10% but this can be changed. Refer to B.3.2.
The TARGET RETURN button (Key E) is used to return the actual sowing rate to
the target sowing rate when a rate change has already been made. Until the rate
has been changed the key is ‘greyed’ out.
Warning: The speed shown may
exceed the practical speed for
the machine and/or conditions.