45
failure, the setting can be changed to ‘Out of work’ so the operation can
continue until the sensor repairs are done.
Min. Speed refers to the minimum operating speed that the motors will
operate proportional to forward speed. All alarms will be disabled below this
speed (except module offline alarms).
Max. Motor Cur. refers to the maximum motor current. When the motors
operating current exceeds this amount for a specific amount of time then an
alarm is initiated and the motor stopped.
C.1.5.3
Bin Configuration
There are four different bin configurations. All bin configuration options
available in the BIN CONFIG screen are shown in Figure 61.