background image

5

T

echnical Data

Fig.1.

 SWITFT6CB driver motherboard view, with indication of most important elements

1

2

3

4

5

6

7

8

9

10

15

18

19

20

17

6

3

5

1

8

9

7

10

11

14

21

22

12

13

P/P

PROG. STOP

2

16

4

4.3. SWIFT6 driver electric connections description
4.3.1. Network power supply clamps 230VAC, 50Hz L, N, PE (1-2, fig.2)

Connect the phase (L), neutral wire (N) to proper clamps. Protective wire (PE) connect directly to the 

body of the engine of SWIFT6 drive.

4.3.2. Clamps for connecting motor CH, C, AP, and condenser … (27-28 and 30-31, fig.2)

Connect the engine of SWIFT6 drive to clamps CH, C, AP. Condenser 16uF/450V must be connected to 

clamps 

 . If while programming the gate opens in the wrong way it is necessary to change wires on clamps CH 

and AP.

4.3.3. Clamps for connecting limit switch FCA, C, FCC (18-20, fig.2)

Clamps  are  used  to  connect  built  in  limit  switch.  Magnets  which  cooperate  with  the  switch  have 

different polarization. Before the programming make manual move with gate and make sure that the switch 
correctly interprets outermost positions of the gate (gate closed - FCC diode turned off, gate opened FCA diode 
turned off; 16, fig. 1). If the switch operates in opposite way turn the magnets 180 degrees after earlier removing 
the cases - catch in the top part of the magnet. Magnet with the tag (white stripe) directed toward the switch 
activates FCC switch (gate closed) and magnet with the tag directed toward the handle activates FCA switch 
(gate open). 

Содержание SWIFT6

Страница 1: ...AUTOMATION SYSTEMS DRIVER FOR SWIFT6 DRIVE Assembly manual for the installers SWIFT6 CB ver 1 0 automation systems ...

Страница 2: ......

Страница 3: ...ards associated with movingofmovablemechanicalelementssuchascrushing hitchingordetachment DTM System company is not responsible for safe and efficient operation of the device in case of applyingcomponentsnotbeing productsofferedbyDTMSystem Useonlyoriginalpartswhileservicing Donotalterorchangetheelementsofthedevice Inform the end user of the manner of the service dealing with breakdown and about th...

Страница 4: ...ver ensures correct and safe operation only when installed and used according to the given safety rules DTM System is not responsible for accidents resulting from incorrect usage or non professional installation of thedevices Please make sure that the persons installing maintaining or operating gate automation follow theseinstructions Itisnecessarytokeeptheseinstructionsinsuchaplacethattheyareeasy...

Страница 5: ...ressureedgesanditalsohasencodersystemefficientlydetectingtheoverloadingcausedby the unintentional resistances in the move of the gate The driver detects and also uses the operation of internal magnetic limit switches of the motor Moreover the driver enables the adjustment of the power and has a functionofslowingdownduringstartandstop Thedriverhasaradioreceiverconnector 3 Technicaldata Basic parame...

Страница 6: ...eters to the current installation inparticularitisnecessaryto 4 alwayssetthepowerofmotors 4 alwayssetopeningandclosingtimesandthelimitofoverloadingsafetybarrier Scrupulously follow designed connections If uncertain do not try but read relevant detailed technical cardsofinstalleddevices Incorrectconnectionscancauseseriousdamageinthedriverandotherdevices 1 Connector powering the transformer 2 Transf...

Страница 7: ...ust be connected to clamps IfwhileprogrammingthegateopensinthewrongwayitisnecessarytochangewiresonclampsCH andAP 4 3 3 ClampsforconnectinglimitswitchFCA C FCC 18 20 fig 2 Clamps are used to connect built in limit switch Magnets which cooperate with the switch have different polarization Before the programming make manual move with gate and make sure that the switch correctlyinterpretsoutermostposi...

Страница 8: ...g opening fast flickering closing 2 flashes countdown of closing time see fig 2 Output load is 100 m A what is sufficient for controllingelectromagnetictransmitters24VAC 4 3 10 ClampsforconnectingphotocellsFT1 11 fig 2 FOTO1 input FT1 is dedicated to the photocell of the gate having the function of stopping the gate movewhileclosing CorrectlyconfiguredJOLLYinput JOL canperformthefunctionofstopping...

Страница 9: ...8 29 30 31 F0 3A 24V motor Rx Tx control board supply 24VAC orange Signal lamp 230VAC Lamp 230VAC OPEN PROG STOP P P CLOSE STEP BY STEP STOP JOLLY PHOTO1 COM photocells with photo test power supply COM MOTOR blue PE ENCODER Transformer power output Control board supply 12VAC white Limit switch supply 24V yellow COM brown FC 1 green FC 2 white CAPACITOR FCC Ap Ch P P Stop Jolly FT1 FCA Supply 230V ...

Страница 10: ...themiddleoftheway 1 fig 3 4 press PROG STOP button and hold it pressed for about 3 seconds until L1 diode does not light constantly 2 fig 3 Driverisintheprogrammingmode 4 Press P P button The gate will start moving in direction toward closing 3 fig 3 If the gate moves on the direction towards opening it is necessary to change the direction of engine operation and limit switch operation seept 4 3 2...

Страница 11: ...Ifthisopeningrequiresmodification actinthefollowingwayusingJOLLYinput clamp10fig 2 4 With the gate closed enter the programming mode by holding the PROG STOP button up to the moment untilaL1diodeturnson 4 PressPEDbutton thegatestartsopening 4 Next press PED button at the moment when the gate reaches the demanding position of opening for pedestrians 4 Thegatestops nextitstartsclosing Thedrivesgoeso...

Страница 12: ...f slowing down standard slowing down increased slowingdownforheavierautomation Procedureofslowingdowntypechange 4 disconnectthedriverpowersupply 4 connectthepowersupplyagainholdingpressedSTOP PROGbuttons 4 L1diodeturnsonafter3seconds 4 still holdingSTOP PROG buttons set DIP SWITCH 9 from theOFF position to theON if DIP SWITCH is set ON switchitontheOFFpositionandnextON 4 L1diodestartspulsing 4 fas...

Страница 13: ...CAUTION SETTINGS CHANGE REQUIRE DRIVE RESTART BY SWITCHING MOTOR SUPPLY OFF FORAMOMENTORBYSHORTCIRCUITOFRESETPINS 15 fig 1 open stop close open close While opening after pressing P P button the gate stops for a few seconds later it closes While closing after pressing P P button the gate stops for a few seconds later it opens always opens While closing pressing P P button stops the gate for a few s...

Страница 14: ...n themotorshouldmakeamovetowardsclosing 4 Sprawdziæ funkcjê ZAMYKANIE u ywaj c przycisku pilota lub przycisku rêcznego PC Przy ca kowicie lub czêœciowo otwartej bramie podaæ impuls z przycisku ZAMYKANIE si ownik powinien wykonaæ ruch w kierunkuzamykania 4 Check STOP function by using manual button During motor move in direction towards closing or opening giveimpulsefromSTOPbutton thedriveshouldsto...

Страница 15: ...tronic devices cannot be removed with everyday waste The correct recycling of devices gives the possibility of keeping natural resources of the Earth for a longer time and prevents the degradation of natural environment ...

Страница 16: ...DTM System spó ka z ograniczon odpowiedzialnoœci spó ka komandytowa ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl desing and production of electronic devices gate automation ...

Отзывы: